ScopeMeter® Série VX190Medical
mAs Measurement Calculates Current
Over Time
Using the cursors, you
can now measure directly the amount of radiation produced by
X-ray systems, or the total amount of charge applied to a system.
Click
image to enlarge.
|
Smart Averaging
Smart averaging gives the averaged waveform over
successive acquisitions, reducing noise in the displayed waveform.
Thanks to smart averaging, you can now also see an incidental
curve of a different waveshape with no effect on the averaged
curve! This allows you to see the averaged curve of a sequence
of video lines, for example, while still seeing the incidental
flyback line flash by! Thanks to smart averaging, the oscilloscope
gives an immediate response when the signal makes large changes,
for instance when probing around different test points, while
retaining the benefits associated with averaging! Click image to enlarge.
|
Extended Offset
Vertical offset is now
extended to a maximum of 16 divisions, allowing vertical zoom-in
for study of small details of the signal. Click image to enlarge.
|
Selectable Persistence
Persistence mode with
selectable decay time helps to find anomalies in the waveshape
and optimizes the display for color information when working
with composite color video. Can be used together with dots only
mode, best for modulated signals, or with dot join mode for more
continuous and stable waveshapes.
Extended Video Triggering
Next to its triggering
capability for standard, interlaced TV signals, the instrument
now triggers on high-resolution, non-interlaced video systems.
The ScopeMeter 190 will trigger on all lines (non-selective),
or can select an individual video line from systems with up to
2800 lines per frame.
MS190 Software Kit
The MS190 Software kit
extends a standard Fluke 190 Series ScopeMeter with the software
functions found in the Fluke 190M ScopeMeter. See Compatibility and Installation Requirements for details.
MA190 Accessory Kit
The MA190 accessory set
enables interconnection of the Fluke 190 for use in the field
of Medical Imaging and Video systems. The kit is included in
the Fluke 190M as a standard.
The accessory kit includes:
- 50 ohm BNC feedthrough
terminator, in insulated enclosure, to maintain proper termination
of test connections during measurement.
- 50 ohm BNC terminator
with 10:1 signal attenuation; keeps test terminal properly loaded
while getting optimum signal amplitude to benefit from the instrumentís
extended offset range.
- 1 ohm current shunt
for current measurements, in insulated enclosure.
- safety-designed BNC
cable, 1.5 m (5 ft), with plastic connectors for safe connection
to test terminals even when not at ground potential.
- insulated BNC(f) to
4 mm banana plug adapter.
- dual 4 mm banana receptacles
(1 red, 1 black).
|