Alimentção & Carga

pm8907.jpg (2033 bytes)ULsmall.jpg (1065 bytes)CSA.jpg (962 bytes)

BC190

17.8V DC 15W

Line Voltage Adapter/Battery Charger
for ScopeMeter 190 Series

PM8907

15V DC 300 mA max.

Line Voltage Adapter/Battery Charger
for ScopeMeter 120 Series

bp120.jpg (3902 bytes)

BP120

NiCd 4.2 V  1800mAh

Battery Pack for ScopeMeter 123, 43(B)

BP130

NiMH 4.2 V 3000 mAh

Battery Pack for ScopeMeter 123 & 124

bp190.jpg (3385 bytes)

BP190

NiMH 7.2V 3,500 mAh

Battery Pack for ScopeMeter 190 Series

Pm9086.jpg (3472 bytes)

PM 9086

NiCd 4.8V2800 mAh

Battery Pack for ScopeMeter 90 Series

 

 

 

BC190/80n Line Voltage Adapter/Battery Charger

pm8907.jpg (5942 bytes)UL.gif (1934 bytes)CSA.gif (3092 bytes)

Provides power cord operation and charging for ScopeMeter 190 Series test tool.
Mains (Line Voltage):
BC190/801 (Europe) 230V ± 10%
BC190/803 (North America) 120V ± 10%
BC190/804 (United Kingdom) 230V ± 10% BC190/806 (Japan) 100V ± 10%
BC190/807 (Australia) 230V ± 10%
BC190/808 (Universal) switchable 115V± 15% or 230V ± 15%. /808 is equipped with a male receptacle plug that must be connected to a line cord appropriate for local use. (Line cord not included)
The North American line plug included
Frequency (all versions): 50…60Hz ± 10%
Output Voltage: 17.8V DC
Output Power: 15W
Power Consumption: 23.7VA
Max.
Voltage to Ground: 600V rms. CAT III per IEC 1010-1

The North American line plug also included in the "stand alone" power adapters BC190/808 or  PM8907/808

powerplugs.gif (33144 bytes)

/808 is equipped with a male receptacle plug that must be connected to a line cord appropriate for local use. (Line cord not included)

The BC190/808 power adapter comes with a universal plug that requires an additional line cord. Also the PM8907/808 has the same universal plug since the introduction of the Fluke 190 series. These adapters are designed for users who travel frequently, and therefore have a switch to select 110V or 230V input voltage. To be able to use these adapters on different systems they come with a universal plug (same type of connection as you find on the rear of a bench computer) this plug requires a locally supplied line cord. Because the most common type of power plug used is the North American power plug, it was decided to include a separate North American line plug, that fits the universal plug directly.

north_american_line_plug.gif (29587 bytes)

Choice has been made to not add a full power cable but to add an adapter to convert the universal plug to a plug that fits the USA type of power socket. Reason is that it is more compact, and not all the ScopeMeter boxes have space left for a complete power cable.

Since Monday April 14 2001 all ScopeMeter products shipped from the Almelo factory that contain the universal adapter BC190/808 or PM8907/808 (also Fluke 123 and Automotive) come with the additional line plug.
Since
March 1, 2002 also the "stand alone" BC190/808 or a PM8907/808, include the North American Line Plug

 

 

 

 

 

 

 

 

PM 8907/80n Line Voltage Adapter/Battery Charger

pm8907.jpg (5942 bytes)Provides power cord operation and charging for ScopeMeter test tool.
Mains (line voltage):
/801 (Europe) 230V ± 10%
/803 (North America) 120V ± 100%
UL.gif (1934 bytes)CSA.gif (3092 bytes)
/804 (United Kingdom) 240V ± 10%
/806 (Japan) 100V ± 10%
/807 (Australia) 240V ± 10%
/808 (Universal) 115V ± 15% or 230V ± 15%
UL.gif (1934 bytes)CSA.gif (3092 bytes)
/808 is equipped with a male receptacle plug that must be connected to a line cord appropriate for local use. (Line cord not included)
The North American line plug included
Frequency (all versions): 50 to 60 Hz ± 10%
Output Voltage: 15V
Output Current: 300 mA max.
Output Plug: 5 mm power jack per DIN 45323
Power Consumption: 10 VA
Max. Voltage to Ground: 600V rms. CAT III per IEC 1010-1

 

 

 

 

 

 

BP120 Battery Pack 120 Series

bp120.jpg (8816 bytes) 

 

Set of four Ni-Cd batteries, designed for use with the Fluke ScopeMeter 120 Series.
Nominal Voltage: 4.8V
Capacity: 1800 mAh
The battery pack can be charged in the instrument. Performing refresh cycles on a regular basis, as provided by the ScopeMeter 120 Series, will strongly contribute to the lifespan of the batteries.

 

 

 

 

BP130 Battery Pack for ScopeMeter 123 & 124

bp120.jpg (8816 bytes)Set of four NiMH batteries, designed for use with the Fluke ScopeMeter 124 and 123 (Fluke 123 support BP130 from Rev 2.0 onwards, see Instrument documentation. BP130 is not supporting previous versions of Fluke 123)
Nominal Voltage: 4.8V
Capacity: 3000 mAh
The battery pack can be charged in the instrument.
Performing refresh cycles on a regular basis, as provided by the ScopeMeter 123 & 124, will strongly contribute to the lifespan of the batteries.

 

 

 

 

 

 

 

 

BP190 Battery Pack ScopeMeter 190 Series

bp190.jpg (8312 bytes) 

 

Set of NiMH batteries designed for use with Fluke ScopeMeter 190 Series.

Nominal Voltage: 7.2V
Capacity: 3,500 mAh
The battery pack can be charged in the instrument.

 

 

 

 

 

 

 

 

 

 

 

 

 

PM 9086/011 Battery Pack 90 series

Pm9086.jpg (10692 bytes) 

 

Set of four Ni-Cd batteries, designed for use with the Fluke ScopeMeter 90 Series.

Nominal voltage: 4.8V
Capacity: 2800 mAh The battery pack can be charged in the instrument.