Calibradores de processo

 

 

 

Calibrador de Processo Multifunção Fluke VX725

Equipamento | Características | Especificações | Modelos, Opções & Acessórios

Measurement Accuracy

Voltage DC

30.000 V 0.02%+ 2 counts (upper display)
30.000 V 0.02%+ 2 counts (lower display)
100.00 mV 0.02%+ 2 counts
-10.00 mV to 75.00 mV 0.025 % + 1 count (via TC connector)

Current DC

24.000 mA 0.02%+ 2 counts

Resistance

0.0 to 400.0 ohms 0.1ohm (4-wire), 0.15ohm (2- and 3-wire)
401 to 1500
ohms 0.5ohm (4-wire), 1ohm (2- and 3-wire)
1500 to 3200
ohms 1ohm (4-wire), 1.5ohm (2- and 3-wire)

Frequency

2.0 to 1000.0 CPM 0.05 % + 1 count
1.0 to 1100.0 Hz 0.05 % + 1 count
1.00 to 10.00 kHz 0.05 % + 1 count
Sensitivity 1 V peak-to-peak-minimum

Pressure

Accuracy from 0.025% of range using any of 29 pressure modules.
(for detailed specifications refer to pressure modules in options and accessories)
Modules available for differential, gage, vacuum, absolute, dual and high pressure.

 

Source Accuracy

Voltage DC

100.00 mV 0.02%+2 counts
10.000 V 0.02%+2 counts
-10.00 mV to 75.00 mV 0.025 % + 1 count (via TC connector)

Current DC

24.000 mA (Source) 0.02%+ 2 counts
24.000 mA (Simulate) 0.02%+ 2 counts

Resistance

15.0 to 400.0 ohms 0.15 ohm (exc. current 0.15 to 0.5 mA), 0.1 ohm (exc. current 0.5 to 2 mA)
401 to 1500
ohms 0.5 ohm(excitation current 0.05 to 0.8 mA)
1500 to 3200
ohms 1 ohm(excitation current 0.05 to 0.4 mA)

Frequency

2.0 to 1000.0 CPM 0.05%
1.0 to 1100.0 Hz 0.05%
1.00 to 10.00 kHz 0.25%
Waveform: 5 V p-p squarewave, -0.1 V offset

 

RTDs and Thermocouples

Measure Accuracy:

NI-120 0.2 C
PT-100 (385) 0.33 C
PT-100 (393) 0.3 C
PT-100 (JIS) 0.3 C
PT-200 (385) 0.2 C
PT-500 (385) 0.3 C
PT-1000 (385) 0.2 C
Resolution: 0.1 C
J: 0.7 C
K: 0.8 C
T: 0.8 C
E: 0.7 C
R: 1.8 C
S: 1.5 C
B: 1.4 C
L: 0.7 C
U: 0.75 C
N: 0.9 C
Resolution J, K, T, E, L, N, U: 0.1 C, 0.1 F B, R, S: 1 C

Source Accuracy:

NI-120 0.2 C
PT-100 (385) 0.33 C
PT-100 (393) 0.3 C
PT-100 (JIS) 0.3 C
PT-200 (385) 0.2 C
PT-500 (385) 0.3 C
PT-1000 (385) 0.2 C
Resolution: 0.1 C
Note: Accuracy stated for 4-wire measurement.
J: 0.7 C
K: 0.8 C
T: 0.8 C
E: 0.7 C
R: 1.4 C
S: 1.5 C
B: 1.4 C
L: 0.7 C
U: 0.75 C
N: 0.9 C
Resolution J, K, T, E, L, N, U: 0.1 C, B, R, S: 1 C

 

Technical Data

Ramp Functions

Source functions: Voltage, current, resistance, frequency, temperature
Ramps Slow ramp, Fast ramp, 25% step-ramp

Loop Power Function

Voltage: 24 V
Accuracy: 10%
Maximum current: 22 mA, short circuit protected

Step Functions

Source functions: Voltage, current, resistance, frequency, temperature
Steps 25% of range, 100% of range

 

Environmental Specifications

Operating Temperature

-10 C to +55 C

Storage Temperature

-20 C to 71 C

Operating Altitude

3000 m

 

Safety Specifications

Agency Approvals

EN 61010-1:1993, ANSI/ISA S82.01-1994; CAN/CSA C22.2 No 1010.1:1992

 

Mechanical & General Specifications

Size

130 x 236 x 61 mm

Weight

0.65 kg

Batteries

4 AA alkaline batteries

Battery Replacement

Separate battery compartment, accessable without breaking calibration seal

Side port connections

Pressure module connector, also used for remote real-time programming

 

 